1. Unscrew the electrode assembly (4) from the multiplier (3).
2. See Figure 6-2. Connect the megohmmeter probes to the electrode (1) and the contact pin (3).
3. The megohmmeter should read between 2 to 10 megohms at 500 volts. If the reading is not in this range, replace the electrode assembly.
4. Check for the electrode assembly for burn-through holes or arc tracks. If found on any parts, replace them.
Output Voltage and Current
|
|
Maximum rated output voltage at the electrode
|
95 kV + 10%
|
Maximum rated output current at the electrode
|
100 uA + 10%
|
Air Pressure
|
|
Purge air
|
5.5−6.5 bar (80−95 psi at 227−255 l/min (8−9 scfm)
|
Gun air
|
0.34 bar (5 psi) 6 l/min (0.2 scfm)
|
Minimum input pressure
|
4.13 bar (60 psi)
|
Maximum input pressure
|
6.89 bar (100 psi)
|